メニュー

Starting/stopping measurement

  •  Starting/stopping measurement

    Smart computer

    Measurement starts automatically when the bicycle moves.

    During measurement the measurement unit flashes.

    * The pause function is not available in Sensor Direct Mode.

  •  Saving measurement data (reset operation)

    Smart computer

    Reset(3 seconds)Pressing and holding MODE when on the measurement screen generates measurement data as summary results and resets measurement data to 0.

    * When MODE has been pressed for 1 second, a smartphone search screen appears, but you should continue to hold down the button.

    * Total Distance (Odo) cannot be reset.

    * The summary data generated is loaded into the smartphone.

    Importing summary data

    Important

    The maximum number of trips that smart computer can save temporarily is 30. If this number is exceeded, the icon appears on the screen, and the oldest summary data is deleted when smart computer is reset.

    When using smart computer with a smartphone, it is recommended to import data regularly.

    ●Resetting Trip Distance 2 (Dst2)

    If Trip Distance 2 (Dst2) is displayed and MODE is pressed for 3 seconds, only Trip Distance 2 is reset to 0.

    * Trip Distance 2 (Dst2) values are not recorded in summary data.

●Functions during measurement

  • Switching measurement data display

    Smart computer

    Pressing MODE switches the measurement data displayed at the bottom of the screen.

    * The data displayed changes depending on the state of the sensor connection.

    * Measurement data will be displayed as [--] if the sensor signal cannot be received.

    *Average values are displayed as .E instead of the measurement value when Elapsed Time exceeds approximately 27 hours. Average speed is also displayed as .E instead of the measurement value when Trip Distance exceeds 1,000 km [620 mile].
    Reset smart computer and start measurement again to enable average value measurement.

    Reset operation

  • Power-saving mode

    Smart computer

    If there is no sensor signal nor button operation for 10 minutes, the power-saving screen is activated. If such a state continues for a further hour, the sleep display is activated.

    The power-saving screen returns to the measurement screen when the bicycle starts moving.

    When left for approx. 10 min

    When left for approx. 60 min

    Power-saving screen

    Measurement screen

    Sleep

  • If you have power sensors

    When a signal is received from a paired power sensor, power is displayed as one of the current functions.

    Smart computer

    Power

    * If a power value is displayed when there is no workload, perform calibration.